Coupling Settings
In this Section we present an overview of the coupling settings.
If not stated otherwise all dictionary files mentioned in this chapter are
located in the constant folder.
Special handling of gravity
The gravity set on the DEM side by the enable_gravity command is transferred to and
also applied on the CFD side when using twoWaySocket. The user
may overrule this setting by providing a different gravity setting in the file
constant/g.
Note
If using a solver based on a formulation involving p_rgh (e.g. a compressible
solver) the presence of constant/g is required. The settings on CFD and DEM side
should match in this case. A warning will be displayed if they deviate.